Teltonika Port Devices Driver Download



Perhaps one of the most popular GPS tracking providers in the world, Teltonika is a European company well known for its high-quality devices. Having started more than 20 years ago in Lithuania, Teltonika set their sites on building powerful Internet of Things (IoT) devices that can help solve their customers’ problems in a user-friendly way. 4386 units of Teltonika FM4200 device type are connected to Wialon Data Center. This represents 0.3% of all AVL Hardware connected. This represents 0.3% of all AVL Hardware connected. Below chart represents the dynamic of connections in the last 30 days. Downloads Manual & documentation. FMB920 Datasheet (En) Updated 2020-12-18. FMB920 Quick Manual (En) Updated 2020-12-18. FMB920 Wiring scheme. Updated 2019-02-08. FMB Firmware Errata (En) FMB devices IO elements AVL ID list (En) Driver & utility. Updated 2019-02-08. Teltonika Configurator (En) Certificates. The Driver Update Tool – is a utility that contains more than 27 million official drivers for all hardware, including port devices drivers. This utility was recognized by many users all over the world as a modern, convenient alternative to manual updating of the drivers and also received a high rating from known computer publications.

Install apropriate drivers. Here is download link. MTK USB Port rocessors System devices Sound, video and game controllers. TELTONIKA TELTONIKA.

This is the approved revision of this page, as well as being the most recent.

PC Connection (Windows)

  1. Power-up FMB1YX with DC voltage (10 – 30 V) power supply using supplied power cable. LED’s should start blinking, see “LED behaviour description”.
  2. Connect device to computer using Micro-USB cable or Bluetooth connection:
    • Using Micro-USB cable
      • You will need to install USB drivers, see 'How to install USB drivers (Windows)'
    • Using Bluetooth
      • FMB1YX Bluetooth is enabled by default. Turn on Bluetooth on your PC, then select Add Bluetooth or other device > Bluetooth. Choose your device named – “FMB1YX_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
  3. You are now ready to use the device on your computer.

How to install USB drivers (Windows)[edit | edit source]

  1. Please download COM port drivers from Teltonika here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
  5. Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

Configuration (Windows)[edit | edit source]

At first FMB1YX device will have default factory settings set. These settings should be changed according to the user's needs.
Main configuration can be performed via Teltonika Configurator software. Get the latest FMB1YX Configurator version from here. Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.

MS .NET requirements
Operating systemMS .NET Framework versionVersionLink
  • Windows Vista
  • Windows 7
  • Windows 8.1
  • Windows 10
MS .NET Framework 4.6.232 and 64 bitwww.microsoft.com

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking in the right bottom corner:

Configuration process begins by pressing on connected device:

After connection to Configurator Status window will be displayed:

Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMB1YX has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

  1. Load from device – loads configuration from device.
  2. Save to device – saves configuration to device.
  3. Load from file – loads configuration from file.
  4. Save to file – saves configuration to file.
  5. Update firmware – updates firmware on device.
  6. Read records – read records from device.
  7. Reboot device – restarts device.
  8. Reset configuration – sets device configuration to default.

Most important configurator section is GPRS – where all your server and GPRS settings can be configured and Data Acquisition – where data acquiring parameters can be configured.More details about FMB1YX configuration using Configurator can be found in the manual.

Quick SMS configuration[edit | edit source]

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:

GPRS settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)

Server settings:

  • 2004 – Domain
  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)
Teltonika

Note: Before SMS text, two space symbols should be inserted.

Default configuration settings
Movement and ignition detection:
Vehicle movement will be detected by accelerometerIgnition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
300 seconds passesVehicle turns 10° degrees
Vehicle drives 100 metersSpeed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
If device has made a record it is sent to the server every 120 seconds

Teltonika Port Devices Driver Download Mac


After successful SMS configuration, FMB1YX device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.

Teltonika Port Devices Driver Download

Retrieved from 'https://wiki.teltonika-gps.com/wikibase/index.php?title=Template:FMB_First_start_config&oldid=58110'